H100


H100 frequency inverters are designed specifically for HVAC (Heating, Ventilation, and Air Conditioning) applications. With their numerous protective and user-friendly features, they ensure stable and energy-efficient operation 24/7, helping to reduce energy consumption.

Pump and fan operation is where frequency inverters can achieve the greatest energy savings and consequently lower operating costs, making the H100 series ideally suited for this purpose.

 

H100 Frequency Inverter – Features

  • Keypad with manual and automatic operation buttons
  • Built-in EMC filter (C3):
  • 0.75–30 kW: standard
  • 37–55 kW: optional
  • 75–90 kW: meets standards without filter
  • 110–500 kW: standard
  • Built-in DC reactor: 37–500 kW
  • Communication modules: RS-485, BACnet MS/TP, Modbus-RTU, Metasys N2, optional LonWorks
  • Free DriveView7 software (USB or Ethernet connection)
  • Soft start and stop functions for pumps
  • Control of 1 main and up to 5 auxiliary motors
  • RTC (Real-Time Clock) module with scheduling capabilities
  • Flow compensation (for long hydraulic connections)
  • Fire Mode
  • Energy savings calculation
  • Pipe leakage detection
  • Motor preheating (prevents condensation)
  • KEB Macro functions

Operating Modes

  • V/f
  • Slip Compensation

Load Ratings

  • 0.75–90 kW: 120 % for 60 s
  • 110–500 kW: 110 % for 60 s

Enclosure – IP20

The IP20 enclosure requires installation inside an electrical cabinet, as it does not provide protection against dust or moisture. It is a classic choice, offering a good balance between cost and performance.

Communication

RS-485 / Modbus RTU, BACnet, Metasys-N2, LonWorks (optional)

LCD Keypad

  • User-friendly LCD keypad, similar to the iS7 and S100 series, standard on all H100 models.
  • Mode selection buttons: manual or automatic operation.
  • Descriptive parameter display during setup and display of up to 4 units (voltage, frequency, current, etc.) during operation.
  • Supports parameter transfer and copy between inverters.
  • Removable design: can be used as an external keypad on cabinet doors with a suitable UTP cable.

Labels

Models

Connections

  • R, S, T: Power supply connection
  • U, V, W: Motor connection
  • P1(+), P2(+): DC reactor connection. If the reactor is not used, the terminals should be short-circuited (applies to H100 up to 30 kW)
  • P2(+), B: Braking resistor connection (applies to H100 up to 30 kW)
  • P2(+), N(-): DC bus input
  • P3(+), N(-): Braking unit connection (applies to H100 from 37 kW)

Input/Output terminals (I/O)

 

 

Catalogs

Instructions and Certificates

Read more...
Filter
Shown 1 - 24 from 24 products
In Stock (3)
Out of stock
In Stock (2)
Out of stock
In Stock (4)
Out of stock
In Stock (1)
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock
Out of stock